Project progress work #200

closed

Parent project #566: [PJ230037]MT MOC Loss analysis system add function for ADVICS

Counter RH fucntion not operation

Added by Santi Srichankaew about 2 years ago. Updated over 1 year ago.

Status:
Closed
Priority:
Normal
Assignee:
Santi Srichankaew
Start date:
04 Nov 2023
Due date:
04 Nov 2023
% Done:

100%

Estimated time:
8.00 h
Spent time:
Finish date:
15 Nov 2023
Programming skills:
DB skills:
OS skills:

Description

Problem
-output PLC HARU machine not send signal.
Action
-check signal ladder plc haru machine found ladder wrong operation.
-Edit program PLC haru machine detect sensor.counter.
Cause
-Programmer haru wrong ladder operation.

Result
-Counter RH normal running.